Hochiki CHQ-DIM2/DIN (HFP)-SCI Analog Addressable Binary Input Module Rail Type with Short Circuit Isolator
SKU: CHQ-DIM2/DIN (HFP)-SCI
Hochiki CHQ-DIM2/DIN (HFP)-SCI is an addressable module used in fire alarm systems.
Hochiki CHQ-DIM2/DIN (HFP)-SCI is an addressable module used in fire alarm systems.
Detailed Information
1. Two Independent Input Channels
- Thanks to two independent input channels, it transmits signals from different devices (e.g. manual call points, flow switches) to the control panel.
- Each input channel can be individually addressed and controlled.
2. Addressable Technology
- It can be addressed with the Dip-Switch on the module and the location of each module can be determined exactly.
- This helps locate the fire quickly.
3. HFP (Hochiki Fire Protocol)
- It provides fast and reliable data communication using Hochiki's proprietary fire protocol.
- It improves the overall performance of the fire alarm system.
4. SCI (Short Circuit Isolator)
- The internal short circuit isolator prevents the spread of damage when a short circuit occurs in the circuit.
- It ensures that the rest of the system continues to operate in the event of a short circuit.
5. Easy Installation and Maintenance
- It has a compact design that can be mounted on a DIN rail.
- It can be easily installed and maintained with its user-friendly assembly and maintenance features.
Technical Specifications
1. Operating Voltage
- 17-41V DC
2. Working Current
- Normally: 1.05 mA
- In Alarm: 2.1 mA
3. Input Channels
- Two independent input channels.
- Inputs can be programmed for different signals such as fire condition or fault condition.
4. Dimensions
- 120 mm x 108 mm x 24 mm (with DIN rail)
5. Weight
- About 150 grams
6. Operating Temperature Range
- -10°C to +50°C
7. Environmental Conditions
- Humidity: Up to 95% relative humidity (non-condensing)
8. LED Indicator
- Status LEDs available (Active, Isolator, Fault)
9. Material
- Highly durable plastic material.
10. Approvals and Certificates
- Complies with EN54-17 (Short Circuit Isolators) and EN54-18 (Input/Output Devices) standards.
- It holds other relevant fire safety certifications.
Areas of Use
- Commercial Buildings: It is used to ensure fire safety in places such as offices, shopping malls and hotels.
- Industrial Facilities: Ideal for controlling signals from different devices in large and complex structures such as factories and warehouses.
- Public Buildings: It is used to increase fire safety in places such as hospitals, schools, and government buildings.
- residences: It can be used to control signals from different devices in places such as apartments and sites.
Advantages
- Versatility: Thanks to two independent input channels, it can control signals from various devices.
- Reliability: Thanks to the internal isolator, it ensures that the rest of the system continues to operate in the event of a short circuit.
- Easy Installation: Thanks to its compact design that can be mounted on a DIN rail, it can be easily installed and maintained.
- Compatibility: Can be easily integrated with existing fire alarm systems.
Hochiki CHQ-DIM2/DIN (HFP)-SCI module is an advanced and reliable solution for controlling signals from various devices in fire alarm systems.
Related Products
Hochiki ATJ-E (HFP) Addressable Heat Detector
Hochiki ATJ-E addressable heat detector is a device used in ...
Hochiki ALN-E (HFP) Addressable Optical Smoke Detector
Hochiki ALN-E addressable optical smoke detector provides hi...
Hochiki CHQ-WS2(HFP) Addressable Fire Alarm Siren
Addressable Electronic Siren (Red) Hochiki model CHQ-WS2 wal...
Hochiki CHQ-WPK Outdoor Kit for Sounders
Addressable Siren External Mounting Kit Hochiki model CHQ-WP...