Hochiki CHQ-DIM2/DIN (HFP)-SCI Analog Addressable Binary Input Module Rail Type with Short Circuit Isolator
SKU: CHQ-DIM2/DIN (HFP)-SCI
Hochiki CHQ-DIM2/DIN (HFP)-SCI is an addressable module used in fire alarm systems.
Hochiki CHQ-DIM2/DIN (HFP)-SCI is an addressable module used in fire alarm systems.
Detailed Information
1. Two Independent Input Channels
- Thanks to two independent input channels, it transmits signals from different devices (e.g. manual call points, flow switches) to the control panel.
- Each input channel can be individually addressed and controlled.
2. Addressable Technology
- It can be addressed with the Dip-Switch on the module and the location of each module can be determined exactly.
- This helps locate the fire quickly.
3. HFP (Hochiki Fire Protocol)
- It provides fast and reliable data communication using Hochiki's proprietary fire protocol.
- It improves the overall performance of the fire alarm system.
4. SCI (Short Circuit Isolator)
- The internal short circuit isolator prevents the spread of damage when a short circuit occurs in the circuit.
- It ensures that the rest of the system continues to operate in the event of a short circuit.
5. Easy Installation and Maintenance
- It has a compact design that can be mounted on a DIN rail.
- It can be easily installed and maintained with its user-friendly assembly and maintenance features.
Technical Specifications
1. Operating Voltage
- 17-41V DC
2. Working Current
- Normally: 1.05 mA
- In Alarm: 2.1 mA
3. Input Channels
- Two independent input channels.
- Inputs can be programmed for different signals such as fire condition or fault condition.
4. Dimensions
- 120 mm x 108 mm x 24 mm (with DIN rail)
5. Weight
- About 150 grams
6. Operating Temperature Range
- -10°C to +50°C
7. Environmental Conditions
- Humidity: Up to 95% relative humidity (non-condensing)
8. LED Indicator
- Status LEDs available (Active, Isolator, Fault)
9. Material
- Highly durable plastic material.
10. Approvals and Certificates
- Complies with EN54-17 (Short Circuit Isolators) and EN54-18 (Input/Output Devices) standards.
- It holds other relevant fire safety certifications.
Areas of Use
- Commercial Buildings: It is used to ensure fire safety in places such as offices, shopping malls and hotels.
- Industrial Facilities: Ideal for controlling signals from different devices in large and complex structures such as factories and warehouses.
- Public Buildings: It is used to increase fire safety in places such as hospitals, schools, and government buildings.
- residences: It can be used to control signals from different devices in places such as apartments and sites.
Advantages
- Versatility: Thanks to two independent input channels, it can control signals from various devices.
- Reliability: Thanks to the internal isolator, it ensures that the rest of the system continues to operate in the event of a short circuit.
- Easy Installation: Thanks to its compact design that can be mounted on a DIN rail, it can be easily installed and maintained.
- Compatibility: Can be easily integrated with existing fire alarm systems.
Hochiki CHQ-DIM2/DIN (HFP)-SCI module is an advanced and reliable solution for controlling signals from various devices in fire alarm systems.
Related Products
Hochiki HFP Latitude Conventional 8 Zone Card
8 Conventional Zones Expansion Card FeaturesNumber of Zones:...
Hochiki Lati-View - Latitude (EN) - Small Panel Package - 4 Panel Licensed Graphics Monitoring Software
Lati-View FeaturesLati-View is a powerful and sophisticated ...
Hochiki Smart Addressable Multi Detector (With CO Sensor) (Excluding Base)
Hochiki ACD Addressable Multi Sensor It has smoke detection,...
Hochiki HFP Vision Repeater Panel (Compatible with Latitude Panels)
The Latitude Vision Network Repeater is a small and unobtrus...