Hochiki CHQ-DZM/DIN (HFP)-SCI Analog Addressable Dual Zone Monitoring Module Rail Type with Short Circuit Isolator
SKU: CHQ-DZM/DIN (HFP)-SCI
Hochiki CHQ-DZM/DIN (HFP)-SCI is an addressable module used in fire alarm systems.
Hochiki CHQ-DZM/DIN (HFP)-SCI is an addressable module used in fire alarm systems.
Detailed Information
1. Two Two-Wire Fire Detector Line (Zone) Control
- It can control two two-wire fire detector lines (zones).
- It can transmit the signals from the detectors and fire alarm buttons on these lines to the control panel.
2. Addressable Technology
- It can be addressed with the Dip Switch on the module and the location of each module can be determined exactly.
- This helps locate the fire quickly.
3. HFP (Hochiki Fire Protocol)
- It provides fast and reliable data communication using Hochiki's proprietary fire protocol.
- It improves the overall performance of the fire alarm system.
4. SCI (Short Circuit Isolator)
- The internal short circuit isolator prevents the spread of damage when a short circuit occurs in the circuit.
- It ensures that the rest of the system continues to operate in the event of a short circuit.
5. Easy Installation and Maintenance
- It has a compact design that can be mounted on a DIN rail.
- It can be easily installed and maintained with its user-friendly assembly and maintenance features.
Technical Specifications
1. Operating Voltage
- 17-41V DC
2. Working Current
- Normally: 500 µA
- In Alarm: 22 mA (maximum)
3. Zone Capacity
- It can control two two-wire fire detector lines (zones).
- A maximum of 32 conventional detectors can be connected to each zone line.
4. Dimensions
- 120 mm x 108 mm x 24 mm (with DIN rail)
5. Weight
- About 150 grams
6. Operating Temperature Range
- -10°C to +50°C
7. Environmental Conditions
- Humidity: Up to 95% relative humidity (non-condensing)
8. LED Indicator
- Status LEDs available (Active, Isolator, Fault)
9. Material
- Highly durable plastic material.
10. Approvals and Certificates
- Complies with EN54-17 (Short Circuit Isolators) and EN54-18 (Input/Output Devices) standards.
- It holds other relevant fire safety certifications.
Areas of Use
- Commercial Buildings: It is used to ensure fire safety in places such as offices, shopping malls and hotels.
- Industrial Facilities: Ideal for controlling fire detector lines in large and complex structures such as factories and warehouses.
- Public Buildings: It is used to increase fire safety in places such as hospitals, schools, and government buildings.
- residences: It can be used to control fire detector lines in places such as apartments and housing estates.
Advantages
- Flexibility: It can control two two-wire fire detector lines (zones).
- Reliability: Thanks to the internal isolator, it ensures that the rest of the system continues to operate in the event of a short circuit.
- Easy Installation: Thanks to its compact design that can be mounted on a DIN rail, it can be easily installed and maintained.
- Compatibility: Can be easily integrated with existing fire alarm systems.
Hochiki CHQ-DZM/DIN (HFP)-SCI module is an advanced and reliable solution for controlling fire detector lines in fire alarm systems.
Related Products
Hochiki Z728 Zener Barrier Single Channel
Zener BarrierI.S.
Hochiki K555 Network Card
HFP Syncro Network Card - K555 FeaturesSyncro Net K555 netwo...
Hochiki CHQ-MRC2/DIN (HFP)-SCI Analog Addressable Main Relay Module Rail Type with Short Circuit Isolator
Hochiki CHQ-MRC2/DIN(SCI) module is an addressable module us...
Hochiki HCP-E SCI(HFP) Smart Addressable Fire Alarm Call Point with Short Circuit Isolator (Excluding Mounting Case)
Addressable Fire Call Button with Short Circuit Isolator Hoc...