Hochiki CHQ-SZM2/DIN (HFP)-SCI Analog Addressable Single Zone Monitoring Module with Short Circuit Isolator
SKU: CHQ-SZM2/DIN (HFP)-SCI
Hochiki CHQ-SZM2/DIN (HFP)-SCI is an addressable module used in fire alarm systems.
Hochiki CHQ-SZM2/DIN (HFP)-SCI is an addressable module used in fire alarm systems.
Detailed Information
1. Two-Wire Fire Detector Line (Zone) Control
- It can control one two-wire fire detector line (zone).
- It can transmit the signals from the detectors and fire alarm buttons on this line to the control panel.
2. Addressable Technology
- It can be addressed with the Dip Switch on the module and the location of each module can be determined exactly.
- This helps locate the fire quickly.
3. HFP (Hochiki Fire Protocol)
- It provides fast and reliable data communication using Hochiki's proprietary fire protocol.
- It improves the overall performance of the fire alarm system.
4. SCI (Short Circuit Isolator)
- The internal short circuit isolator prevents the spread of damage when a short circuit occurs in the circuit.
- It ensures that the rest of the system continues to operate in the event of a short circuit.
5. Easy Installation and Maintenance
- It has a compact design that can be mounted on a DIN rail.
- It can be easily installed and maintained with its user-friendly assembly and maintenance features.
Technical Specifications
1. Operating Voltage
- 17-41V DC
2. Working Current
- Normally: 500 µA
- In Alarm: 22 mA (maximum)
3. Zone Capacity
- It can control one two-wire fire detector line (zone).
- A maximum of 32 conventional detectors can be connected.
4. Dimensions
- 120 mm x 108 mm x 24 mm (with DIN rail)
5. Weight
- About 150 grams
6. Operating Temperature Range
- -10°C to +50°C
7. Environmental Conditions
- Humidity: Up to 95% relative humidity (non-condensing)
8. LED Indicator
- Status LEDs available (Active, Isolator, Fault)
9. Material
- Highly durable plastic material.
10. Approvals and Certificates
- Complies with EN54-17 (Short Circuit Isolators) and EN54-18 (Input/Output Devices) standards.
- It holds other relevant fire safety certifications.
Areas of Use
- Commercial Buildings: It is used to ensure fire safety in places such as offices, shopping malls and hotels.
- Industrial Facilities: Ideal for controlling fire detector lines in large and complex structures such as factories and warehouses.
- Public Buildings: It is used to increase fire safety in places such as hospitals, schools, and government buildings.
- residences: It can be used to control fire detector lines in places such as apartments and housing estates.
Advantages
- Flexibility: It can control one two-wire fire detector line (zone).
- Reliability: Thanks to the internal isolator, it ensures that the rest of the system continues to operate in the event of a short circuit.
- Easy Installation: Thanks to its compact design that can be mounted on a DIN rail, it can be easily installed and maintained.
- Compatibility: Can be easily integrated with existing fire alarm systems.
Hochiki CHQ-SZM2/DIN (HFP)-SCI module is an advanced and reliable solution for controlling fire detector lines in fire alarm systems.
Related Products
Hochiki CHQ-PCM(HFP)-SCI Analog Addressable Facility Control Module with Short Circuit Isolator
Facility Control Module Hochiki model CHQ-PCM facility contr...
Hochiki CHQ-SIM(HFP) Single Input Module
Single Input Module Hochikimodel CHQ-SIM is designed to conn...
Hochiki Hybrid Wireless Optical Smoke Detector
EK-WL8-O Hybrid Wireless Optical Smoke Detector is the lates...
Hochiki Lati-View Syncro/Syncro AS (EN) - Small Panel Package 64 Panels Licensed